Open Access System for Information Sharing

Login Library

 

Article
Cited 20 time in webofscience Cited 21 time in scopus
Metadata Downloads
Full metadata record
Files in This Item:
DC FieldValueLanguage
dc.contributor.authorPark, J.-
dc.contributor.authorLee, K.-P.-
dc.contributor.authorKim, H.-
dc.contributor.authorPark, S.-
dc.contributor.authorWijesinghe, R.E.-
dc.contributor.authorLee, J.-
dc.contributor.authorHan, S.-
dc.contributor.authorLee, S.-
dc.contributor.authorKim, P.-
dc.contributor.authorCho, D.-W.-
dc.contributor.authorJang, J.-
dc.contributor.authorKim, H.-
dc.contributor.authorJeon, M.-
dc.contributor.authorKim, J.-
dc.date.accessioned2019-12-04T04:50:35Z-
dc.date.available2019-12-04T04:50:35Z-
dc.date.created2019-08-07-
dc.date.issued2019-06-
dc.identifier.issn1864-063X-
dc.identifier.urihttps://oasis.postech.ac.kr/handle/2014.oak/100268-
dc.description.abstractCorneal transplantation by full-thickness penetrating keratoplasty with human donor tissue is a widely accepted treatment for damaged or diseased corneas. Although corneal transplantation has a high success rate, a shortage of high-quality donor tissue is a considerable limitation. Therefore, bioengineered corneas could be an effective solution for this limitation, and a decellularized extracellular matrix comprises a promising scaffold for their fabrication. In this study, three-dimensional bioprinted decellularized collagen sheets were implanted into the stromal layer of the cornea of five rabbits. We performed in vivo noninvasive monitoring of the rabbit corneas using swept-source optical coherence tomography (OCT) after implanting the collagen sheets. Anterior segment OCT images and averaged amplitude-scans were acquired biweekly to monitor corneal thickness after implantation for 1 month. The averaged cornea thickness in the control images was 430.3 +/- 5.9 mu m, while the averaged thickness after corneal implantation was 598.5 +/- 11.8 mu m and 564.5 +/- 12.5 mu m at 2 and 4 weeks, respectively. The corneal thickness reduction of 34 mu m confirmed the biocompatibility through the image analysis of the depth-intensity profile base. Moreover, hematoxylin and eosin staining supported the biocompatibility evaluation of the bioprinted decellularized collagen sheet implantation. Hence, the developed bioprinted decellularized collagen sheets could become an alternative solution to human corneal donor tissue, and the proposed image analysis procedure could be beneficial to confirm the success of the surgery.-
dc.languageEnglish-
dc.publisherWILEY-V C H VERLAG GMBH-
dc.relation.isPartOfJOURNAL OF BIOPHOTONICS-
dc.titleBiocompatibility evaluation of bioprinted decellularized collagen sheet implanted in vivo cornea using swept-source optical coherence tomography-
dc.typeArticle-
dc.identifier.doi10.1002/jbio.201900098-
dc.type.rimsART-
dc.identifier.bibliographicCitationJOURNAL OF BIOPHOTONICS-
dc.identifier.wosid000478541500001-
dc.citation.titleJOURNAL OF BIOPHOTONICS-
dc.contributor.affiliatedAuthorKim, H.-
dc.contributor.affiliatedAuthorCho, D.-W.-
dc.contributor.affiliatedAuthorJang, J.-
dc.identifier.scopusid2-s2.0-85069943264-
dc.description.journalClass1-
dc.description.journalClass1-
dc.description.isOpenAccessY-
dc.type.docTypeArticle; Early Access-
dc.subject.keywordPlusBiocompatibility-
dc.subject.keywordPlusCollagen-
dc.subject.keywordPlusImage analysis-
dc.subject.keywordPlusImage segmentation-
dc.subject.keywordPlusScaffolds (biology)-
dc.subject.keywordPlusTissue-
dc.subject.keywordPlusTomography-
dc.subject.keywordPlusAlternative solutions-
dc.subject.keywordPlusbioprinted collagen sheet-
dc.subject.keywordPlusCorneal implants-
dc.subject.keywordPlusCorneal transplantation-
dc.subject.keywordPlusExtracellular matrices-
dc.subject.keywordPlusNon-invasive monitoring-
dc.subject.keywordPlusPenetrating keratoplasty-
dc.subject.keywordPlusSwept source optical coherence tomographies-
dc.subject.keywordPlusOptical tomography-
dc.subject.keywordAuthorbiocompatibility-
dc.subject.keywordAuthorbioprinted collagen sheet-
dc.subject.keywordAuthorcorneal implant-
dc.subject.keywordAuthornoninvasive monitoring-
dc.subject.keywordAuthoroptical coherence tomography-
dc.relation.journalWebOfScienceCategoryBiochemical Research Methods-
dc.relation.journalWebOfScienceCategoryBiophysics-
dc.relation.journalWebOfScienceCategoryOptics-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaBiochemistry & Molecular Biology-
dc.relation.journalResearchAreaBiophysics-
dc.relation.journalResearchAreaOptics-

qr_code

  • mendeley

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher

조동우CHO, DONG WOO
Dept of Mechanical Enginrg
Read more

Views & Downloads

Browse