Open Access System for Information Sharing

Login Library

 

Conference
Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads
Full metadata record
Files in This Item:
There are no files associated with this item.
DC FieldValueLanguage
dc.contributor.authorJeon, Seungwan-
dc.contributor.authorPark, Eun-Yeong-
dc.contributor.authorChoi, Wonseok-
dc.contributor.authorManaguli, Ravi-
dc.contributor.authorLee, Ki Jong-
dc.contributor.authorKIM, CHULHONG-
dc.date.accessioned2020-04-07T22:50:50Z-
dc.date.available2020-04-07T22:50:50Z-
dc.date.created2020-04-06-
dc.date.issued2020-02-17-
dc.identifier.urihttps://oasis.postech.ac.kr/handle/2014.oak/102527-
dc.description.abstractDelay-and-sum (DAS) beamforming is the most commonly used algorithm to form photoacoustic (PA) and ultrasound (US) images because of its simple implementation. However, it has several drawbacks such as low image resolution and contrast. To deal with this problem, delay-multiply-and-sum (DMAS) beamforming algorithm was developed a few years ago. It is known that DMAS can improve the image quality by providing higher contrast and narrower main lobe compared to DAS, but its calculation speed is too slow to be implemented for clinical applications. Herein, we introduce an improved DMAS in terms of both imaging speed and quality, and we demonstrated real-time clinical PA imaging. The proposed DMAS provided better lateral resolution and signal-to-noise ratio (SNR) than the original DMAS through a modified coherence factor. Then we accelerated its computation speed by optimizing the algorithm and parallelizing the process using a graphics processing unit (GPU). We quantitatively compared the processing time and the image quality of the proposed algorithm with the conventional algorithms. As the result, it was observed that our proposed algorithm showed better spatial resolution and SNR while achieving real-time imaging framerate. Due to the improvement, the proposed algorithm was successfully implemented on a programmable clinical PA/US imaging system and showed clearer real-time PA images than the conventional DAS images.-
dc.languageEnglish-
dc.publisherSPIE-
dc.relation.isPartOfPhotonics West, Conference on Biomedical Optics-
dc.relation.isPartOfProceedings of SPIE-
dc.titleImproved real-time delay-multiply-and-sum beamforming with coherence factor-
dc.typeConference-
dc.type.rimsCONF-
dc.identifier.bibliographicCitationPhotonics West, Conference on Biomedical Optics-
dc.citation.conferenceDate2020-02-01-
dc.citation.conferencePlaceUS-
dc.citation.conferencePlaceSan Francisco-
dc.citation.titlePhotonics West, Conference on Biomedical Optics-
dc.contributor.affiliatedAuthorKIM, CHULHONG-
dc.identifier.scopusid2-s2.0-85082678562-
dc.description.journalClass1-
dc.description.journalClass1-

qr_code

  • mendeley

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Views & Downloads

Browse