Extraction of LRGC matrices for 8-coupled uniform Lossy transmission lines using 2-port VNA measurements SCIE SCOPUS

Title
Extraction of LRGC matrices for 8-coupled uniform Lossy transmission lines using 2-port VNA measurements
Authors
Lee, HBLee, KJung, HKPark, HJ
Date Issued
2006-03
Publisher
IEICE-INST ELECTRONICS INFORMATION CO
Abstract
The electrical parameters (8 x 8 LRGC matrices) of 8-coupled uniform lossy transmission lines were extracted from 40 S-parameter values measured by using 2-port VNA measurements, where all the ports other than 2 VNA ports were terminated by 50 ohm chip resistors. It was assumed in the extraction step that the transmission lines are weakly-coupled, and that the resistance values of all the termination chip resistors are exactly 50 ohms with the second reflections neglected. Comparison of the extracted LRGC matrix components with those from a commercial 3D field solver revealed on average and a maximum relative difference of 2.45% and 7.66%, respectively. In addition, the time-domain crosstalk voltage waveforms in the measured data and those in the SPICE simulation results using the extracted LRGC parameters agreed very well with the average difference and the maximum relative difference in peak crosstalk voltages of 4.15% and 9.68%, respectively.
URI
https://oasis.postech.ac.kr/handle/2014.oak/10290
DOI
10.1093/ietele/e89-c.3.410
ISSN
0916-8524
Article Type
Article
Citation
IEICE TRANSACTIONS ON ELECTRONICS, vol. E89C, no. 3, page. 410 - 419, 2006-03