Open Access System for Information Sharing

Login Library

 

Article
Cited 2 time in webofscience Cited 2 time in scopus
Metadata Downloads
Full metadata record
Files in This Item:
There are no files associated with this item.
DC FieldValueLanguage
dc.contributor.authorKIM, JIN-KWANG-
dc.contributor.authorCASA, DIEGO-
dc.contributor.authorHUANG, XIANRONG-
dc.contributor.authorGOG, THOMAS-
dc.contributor.authorKIM, BUMJOON-
dc.contributor.authorKIM, JUNGHO-
dc.date.accessioned2021-01-27T14:50:30Z-
dc.date.available2021-01-27T14:50:30Z-
dc.date.created2020-11-16-
dc.date.issued2020-06-
dc.identifier.issn1600-5775-
dc.identifier.urihttps://oasis.postech.ac.kr/handle/2014.oak/104945-
dc.description.abstractResonant inelastic X-ray scattering (RIXS) is increasingly playing a significant role in studying highly correlated systems, especially since it was proven capable of measuring low-energy magnetic excitations. However, despite high expectations for experimental evidence of novel magnetic phases at high pressure, unequivocal low-energy spectral signatures remain obscured by extrinsic scattering from material surrounding the sample in a diamond anvil cell (DAC): pressure media, Be gasket and the diamond anvils themselves. A scattered X-ray collimation based medium-energy resolution (similar to 100meV) analyzer system for a RIXS spectrometer at the Ir L-3-absorption edge has been designed and built to remediate these difficulties. Due to the confocal nature of the analyzer system, the majority of extrinsic scattering is rejected, yielding a clean low-energy excitation spectrum of an iridate Sr2IrO4 sample in a DAC cell. Furthermore, the energy resolution of different configurations of the collimating and analyzing optics are discussed.-
dc.languageEnglish-
dc.publisherWiley-Blackwell-
dc.relation.isPartOfJournal of synchrotron radiation-
dc.titleMontel mirror based collimating analyzer system for high-pressure resonant inelastic X-ray scattering experiments-
dc.typeArticle-
dc.identifier.doi10.1107/S1600577520005792-
dc.type.rimsART-
dc.identifier.bibliographicCitationJournal of synchrotron radiation, v.27, pp.963 - 969-
dc.identifier.wosid000546241000012-
dc.citation.endPage969-
dc.citation.startPage963-
dc.citation.titleJournal of synchrotron radiation-
dc.citation.volume27-
dc.contributor.affiliatedAuthorKIM, JIN-KWANG-
dc.contributor.affiliatedAuthorKIM, BUMJOON-
dc.identifier.scopusid2-s2.0-85089498076-
dc.description.journalClass1-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.type.docTypeARTICLE-
dc.subject.keywordAuthorresonant inelastic X-ray scattering-
dc.subject.keywordAuthorhigh pressure-
dc.subject.keywordAuthorscattered X-ray collimation-
dc.subject.keywordAuthorMontel mirror-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryOptics-
dc.relation.journalWebOfScienceCategoryPhysics, Applied-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalResearchAreaOptics-
dc.relation.journalResearchAreaPhysics-

qr_code

  • mendeley

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Views & Downloads

Browse