Monitoring real-time contractility of 3D engineered heart tissues by printing a strain gauge-embedded microphysiological system
- Title
- Monitoring real-time contractility of 3D engineered heart tissues by printing a strain gauge-embedded microphysiological system
- Authors
- Yong, Uijung; Kim, Donghwan; Hwang, Dong Gyu; Nam, Hyoryung; Cho, Sungkeon; Cho, Seungyeun; Lee, Seokho; Kim, Jihwan; Jang, Jinah
- Date Issued
- 2020-11-16
- Publisher
- 한국정밀공학회
- Abstract
- There are the growing interests in microphysiological systems (MPS), also known as organs-on-chips,
recapitulating human-like physiology. Mechanical contraction is important factor affecting the development of
engineered heart tissue (EHT). In addition, each cardiomyocyte (CM) in EHT should contract synergistically with
consistency to conduct its own function. Currently, there are several methods to monitor the contractile force of
CMs. The force transducer is to measure the contractile force directly by connecting the 3D EHT with transducer
in real-time. However, this method is inevitable to damage to the 3D EHT for measuring the contractility because
the tissue should be connected to the force transducer by using a clamp or hook. Next, optical readout system
utilizes the principle of Hooke’s law and the displacement is measured by optical camera. Although this system can
invasively measure the contractile force of tissue constructs without damaging them, this analysis requires huge
amount of data for real-time analysis. Also, Piezoresistive cantilever is used to measure the change of resistance
induced by the deflection due to the mechanical contraction of monolayer of cardiomyocytes on the cantilever. This
method is eligible to monitor the contractility in real-time, however, artificial forces, such as the stiffness of the
cantilever, are applied to monolayer cells, inhibiting tissue generation from native cell-cell contact. In this
research, we propose the strain gauge-embedded MPS integrated with the two-post platform, which is optimized to
quantify or monitor beating rate, rhythm, and contractility of 3D EHT. To fabricate suggested system that is
composed of strain gauge embedded multiple layers and two posts, three materials are sequentially extruded by
multi-head 3D printing technique: biocompatible thermoplastic polymer, sacrificial polymer, and conductive
polymer that is a mixture of carbon black and silicone elastomer. Biocompatible thermoplastic polymer is used to
print a base layer and two-post structure that will be exposed to contractile stress and cells. Next, sacrificial
polymer is used to print a sacrificial layer, and conductive polymer is utilized to make the strain gauge sensor and
electrodes. To show the feasibility of developed system, the change of electrical resistance was measured by a
multimeter. In addition, the deformation, induced by the well-known contractile force of CMs, was analyzed using
commercial finite element analysis program (ANSYS). Ultimately, we are expecting that suggested system can be
used for studying drug responses or the contractile development of human stem cell-derived cardiac tissues later.