Open Access System for Information Sharing

Login Library

 

Article
Cited 4 time in webofscience Cited 6 time in scopus
Metadata Downloads

Laparoscopic Ablation System for Complete Circumferential Renal Sympathetic Denervation SCIE SCOPUS

Title
Laparoscopic Ablation System for Complete Circumferential Renal Sympathetic Denervation
Authors
Baik, JinhwanKim, HwanikLee, SangyongPark, Dae HyoungDo, Minh-TungLee, Hae-YongChoi, Eue-KeunYang, SunchoelJeong, Chang WookPark, Sung-min
Date Issued
2021-11
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Abstract
Goal: The catheter-based renal denervation (RDN) showed promising results for patients in lowering BP, but there were also many non-responders. One of the possible reasons was the incomplete neural ablation due to the ablation of renal nerves at random sites resulting in asymmetric innervation patterns along the renal artery. Methods: We developed a laparoscopic ablation system that is optimized for complete RDN regardless of renal arterial innervation and size. To demonstrate its effectiveness, we evaluated the system using computational simulation and 28-day survival model using pigs. Results: The ablations were focused around the tunica externa, and the ablation patterns could be predicted numerically during RDN treatment. In the animal study, the mean reduction of systolic BP and diastolic BP in the bilateral main renal arteries was 22.8 mmHg and 14.4 mmHg (P<0.001), respectively. The respond to immunostaining targeting tyrosine hydroxylase was significantly reduced at treatment site (108.2 +/- 7.5 (control) vs. 63.4 +/- 8.7 (treatment), P<0.001), and an increased degree of sympathetic signals interruption to kidneys was associated with the efficacy of RDN. Conclusion: The laparoscopic ablation system achieved complete circumferential RDN at the treatment site and could numerically predict the ablation patterns. Significance: These findings clearly suggest that the proposed system can significantly improve the RDN effectiveness by reducing the variation to the percentage of injured nerves and open up a new opportunity to treat uncontrolled hypertension.
URI
https://oasis.postech.ac.kr/handle/2014.oak/108520
DOI
10.1109/TBME.2021.3064567
ISSN
0018-9294
Article Type
Article
Citation
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, vol. 68, no. 11, page. 3217 - 3227, 2021-11
Files in This Item:
There are no files associated with this item.

qr_code

  • mendeley

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Views & Downloads

Browse