dc.description.abstract | Ambulatory blood pressure monitoring (ABPM) has become essential to diagnose the hypertension. In the fast few decades, commercialized blood pressure monitor used oscillometric cuff-based methods which is cumbersome and unsuitable for ABPM due to the discomfort it cause to the patients. In this study, we developed the prototype of cuff-less blood pressure monitor to validate cuff-less BP estimation algorithm. Sixteen subjects were participated in the experiment to test the accuracy of the device compared to the cuff-based BP monitor using oscillometric method. Experimental results using Bland-Altman plot showed that the mean and standard deviation of error of systolic BP (SBP) and diastolic BP (DBP) were 0.3 +/- 6.6 and 1.7 +/- 9.1 respectively. | - |
dc.language | English | - |
dc.publisher | IEEE | - |
dc.relation.isPartOf | TENCON 2018 - 2018 IEEE Region 10 Conference | - |
dc.title | Validation of Cuffless Blood Pressure Monitoring Using Wearable Device | - |
dc.type | Article | - |
dc.identifier.doi | 10.1109/tencon.2018.8650069 | - |
dc.type.rims | ART | - |
dc.identifier.bibliographicCitation | TENCON 2018 - 2018 IEEE Region 10 Conference, pp.416 - 419 | - |
dc.identifier.wosid | 000465799100080 | - |
dc.citation.endPage | 419 | - |
dc.citation.startPage | 416 | - |
dc.citation.title | TENCON 2018 - 2018 IEEE Region 10 Conference | - |
dc.contributor.affiliatedAuthor | Park, Sung-Min | - |
dc.identifier.scopusid | 2-s2.0-85063227495 | - |
dc.description.journalClass | 1 | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | N | - |
dc.type.docType | Proceedings Paper | - |
dc.subject.keywordAuthor | Wearable | - |
dc.subject.keywordAuthor | pulse arrival time | - |
dc.subject.keywordAuthor | cuffless blood pressure | - |
dc.subject.keywordAuthor | electrocardiogram | - |
dc.subject.keywordAuthor | photoplethysmogram | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
library@postech.ac.kr Tel: 054-279-2548
Copyrights © by 2017 Pohang University of Science ad Technology All right reserved.