Open Access System for Information Sharing

Login Library

 

Article
Cited 55 time in webofscience Cited 59 time in scopus
Metadata Downloads
Full metadata record
Files in This Item:
There are no files associated with this item.
DC FieldValueLanguage
dc.contributor.authorBAEK, SANGHOON-
dc.contributor.authorLee, Youngoh-
dc.contributor.authorBaek, JinHyeok-
dc.contributor.authorKWON, JIMIN-
dc.contributor.authorKIMSEONGJU-
dc.contributor.authorLee, Seungjae-
dc.contributor.authorStrunk, Karl-Philipp-
dc.contributor.authorStehlin, Sebastian-
dc.contributor.authorMelzer, Christian-
dc.contributor.authorPARK, SUNG MIN-
dc.contributor.authorKo, Hyunhyub-
dc.contributor.authorJUNG, SUNGJUNE-
dc.date.accessioned2022-03-02T07:20:07Z-
dc.date.available2022-03-02T07:20:07Z-
dc.date.created2022-02-28-
dc.date.issued2022-01-
dc.identifier.issn1936-0851-
dc.identifier.urihttps://oasis.postech.ac.kr/handle/2014.oak/110079-
dc.description.abstractWearable pressure sensors have demonstrated great potential in detecting pulse pressure waves on the skin for the noninvasive and continuous diagnosis of cardiac conditions. However, difficulties lie in positioning conventional single-point sensors on an invisible arterial line, thereby preventing the detection of adequate signal amplitude for accurate pulse wave analysis. Herein, we introduce the spatiotemporal measurements of arterial pulse waves using wearable active-matrix pressure sensors to obtain optimal pulse waveforms. We fabricate thin-film transistor (TFT) arrays with high yield and uniformity using inkjet printing where array sizes can be customizable and integrate them with highly sensitive piezoresistive sheets. We maximize the pressure sensitivity (16.8 kPa(-1)) and achieve low power consumption (10(1) nW) simultaneously by strategically modulating the TFT operation voltage. The sensor array creates a spatiotemporal pulse wave map on the wrist. The map presents the positional dependence of pulse amplitudes, which allows the positioning of the arterial line to accurately extract the augmentation index, a parameter for assessing arterial stiffness. The device overcomes the positional inaccuracy of conventional single-point sensors, and therefore, it can be used for medical applications such as arterial catheter injection or the diagnosis of cardiovascular disease in daily life.-
dc.languageEnglish-
dc.publisherAmerican Chemical Society-
dc.relation.isPartOfACS Nano-
dc.titleSpatiotemporal Measurement of Arterial Pulse Waves Enabled by Wearable Active-Matrix Pressure Sensor Arrays-
dc.typeArticle-
dc.identifier.doi10.1021/acsnano.1c06695-
dc.type.rimsART-
dc.identifier.bibliographicCitationACS Nano, v.16, no.1, pp.368 - 377-
dc.identifier.wosid000733811000001-
dc.citation.endPage377-
dc.citation.number1-
dc.citation.startPage368-
dc.citation.titleACS Nano-
dc.citation.volume16-
dc.contributor.affiliatedAuthorBAEK, SANGHOON-
dc.contributor.affiliatedAuthorKWON, JIMIN-
dc.contributor.affiliatedAuthorKIMSEONGJU-
dc.contributor.affiliatedAuthorPARK, SUNG MIN-
dc.contributor.affiliatedAuthorJUNG, SUNGJUNE-
dc.identifier.scopusid2-s2.0-85121917531-
dc.description.journalClass1-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.type.docTypeArticle-
dc.subject.keywordPlusLARGE-AREA-
dc.subject.keywordPlusBLOOD-PRESSURE-
dc.subject.keywordPlusSKIN-
dc.subject.keywordPlusDISEASE-
dc.subject.keywordAuthorwearable pulse wave sensors-
dc.subject.keywordAuthororganic transistors-
dc.subject.keywordAuthorpressure sensors-
dc.subject.keywordAuthoractive-matrix-
dc.subject.keywordAuthorinkjet printing-
dc.subject.keywordAuthorsoft sensor arrays-
dc.subject.keywordAuthorlow power consumption-
dc.relation.journalWebOfScienceCategoryChemistry, Multidisciplinary-
dc.relation.journalWebOfScienceCategoryChemistry, Physical-
dc.relation.journalWebOfScienceCategoryNanoscience & Nanotechnology-
dc.relation.journalWebOfScienceCategoryMaterials Science, Multidisciplinary-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-

qr_code

  • mendeley

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Views & Downloads

Browse