Open Access System for Information Sharing

Login Library

 

Article
Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A Preliminary Study on Evaluation of Time-Dependent Radionuclide Removal Performance Using Artificial Intelligence for Biological Adsorbents SCOPUS KCI

Title
A Preliminary Study on Evaluation of Time-Dependent Radionuclide Removal Performance Using Artificial Intelligence for Biological Adsorbents
Authors
LEE, JANGHEEJang, SeungsooLEE, MIN JAECho, Woo-SungKim, Joo YeonHan, SangsooShin, Sung GyunLee, Sun YoungJang, Dae HyukYun, MiyongKim, Song Hyun
Date Issued
2023-12
Publisher
대한방사선방어학회
Abstract
Background: Recently, biological adsorbents have been developed for removing radionuclides from radioactive liquid waste due to their high selectivity, eco-friendliness, and renewability. However, since they can be damaged by radiation in radioactive waste, a method for estimating the bio-adsorbent performance as a time should consider the radiation damages in terms of their renewability. This paper aims to develop a simulation method that applies a deep learning technique to rapidly and accurately estimate the adsorption performance of bio-adsorbents when inserted into liquid radioactive waste. Materials and Methods: A model that describes various interactions between a bio-adsorbent and liquid has been constructed using numerical methods to estimate the adsorption capacity of the bio-adsorbent. To generate datasets for machine learning, Monte Carlo N-Particle (MCNP) simulations were conducted while considering radioactive concentrations in the adsorbent column. Results and Discussion: Compared with the result of the conventional method, the proposed method indicates that the accuracy is in good agreement, within 0.99% and 0.06% for the R2 score and mean absolute percentage error, respectively. Furthermore, the estimation speed is improved by over 30 times. Conclusion: Note that an artificial neural network can rapidly and accurately estimate the survival rate of a bio-adsorbent from radiation ionization compared with the MCNP simulation and can determine if the bio-adsorbents are reusable. © 2023 The Korean Association for Radiation Protection.
URI
https://oasis.postech.ac.kr/handle/2014.oak/123071
DOI
10.14407/jrpr.2023.00094
ISSN
2508-1888
Article Type
Article
Citation
Journal of Radiation Protection and Research, vol. 48, no. 4, page. 175 - 183, 2023-12