SOFT-X-RAY AMPLIFICATION IN A CAPILLARY DISCHARGE
SCIE
SCOPUS
- Title
- SOFT-X-RAY AMPLIFICATION IN A CAPILLARY DISCHARGE
- Authors
- KIM, DE; LEE, TN; SHIN, HJ
- Date Issued
- 1994-08
- Publisher
- AMERICAN PHYSICAL SOC
- Abstract
- Soft-x-ray amplification in the C VI Balmer alpha transition is observed in a capillary discharge. The capillary is made of polyethylene with a bore diameter of 1.2 mm. A hot and dense carbon plasma which is formed on the capillary axis region expands radially and collides with the wall where it undergoes a rapid cooling and subsequent recombination. The amplification takes place in this cool (T(e) approximately 13 eV) plasma region, according to space-resolved spectral data obtained using a 2-m grazing incidence spectrograph. The gain coefficient is measured to be 2.8 cm-1.
- URI
- https://oasis.postech.ac.kr/handle/2014.oak/12331
- DOI
- 10.1103/PhysRevE.50.1376
- ISSN
- 1539-3755
- Article Type
- Article
- Citation
- PHYSICAL REVIEW E, vol. 50, no. 2, page. 1376 - 1382, 1994-08