Open Access System for Information Sharing

Login Library

 

Article
Cited 11 time in webofscience Cited 11 time in scopus
Metadata Downloads
Full metadata record
Files in This Item:
There are no files associated with this item.
DC FieldValueLanguage
dc.contributor.authorJung, Y-
dc.contributor.authorJeong, S-
dc.contributor.authorNayoun, W-
dc.contributor.authorAhn, B-
dc.contributor.authorKwag, J-
dc.contributor.authorKim, SG-
dc.contributor.authorKim, S-
dc.date.accessioned2015-09-16T02:35:15Z-
dc.date.available2015-09-16T02:35:15Z-
dc.date.created2015-07-28-
dc.date.issued2015-04-
dc.identifier.issn1083-3668-
dc.identifier.other2015-OAK-0000033459-
dc.identifier.urihttps://oasis.postech.ac.kr/handle/2014.oak/13338-
dc.description.abstractQuantum dot (QD) imaging capability was investigated by the imaging depth at a near-infrared second optical window (SOW; 1000 to 1400 nm) using time-modulated pulsed laser excitations to control the effective fluence rate. Various media, such as liquid phantoms, tissues, and in vivo small animals, were used and the imaging depths were compared with our predicted values. The QD imaging depth under excitation of continuous 20 mW/cm(2) laser was determined to be 10.3 mm for 2 wt% hemoglobin phantom medium and 5.85 mm for 1 wt% intralipid phantom, which were extended by more than two times on increasing the effective fluence rate to 2000 mW/cm(2). Bovine liver and porcine skin tissues also showed similar enhancement in the contrast-tonoise ratio (CNR) values. A QD sample was inserted into the abdomen of a mouse. With a higher effective fluence rate, the CNR increased more than twofold and the QD sample became clearly visualized, which was completely undetectable under continuous excitation. Multiple acquisitions of QD images and averaging process pixel by pixel were performed to overcome the thermal noise issue of the detector in SOW, which yielded significant enhancement in the imaging capability, showing up to a 1.5 times increase in the CNR. (C) 2015 Society of Photo-Optical Instrumentation Engineers (SPIE)-
dc.description.statementofresponsibilityopen-
dc.languageEnglish-
dc.publisherSPIE-SOC PHOTO-OPTICAL INSTRUMENTATION ENGINEERS-
dc.relation.isPartOfJOURNAL OF BIOMEDICAL OPTICS-
dc.subjectquantum dots-
dc.subjectinfrared imaging-
dc.subjectcharge-coupled devices-
dc.subjectfluorescence-
dc.subjectimage enhancement-
dc.subjectTO-NOISE RATIO-
dc.subjectIN-VIVO-
dc.subjectNANOCRYSTALS-
dc.subjectPBS-
dc.titleQuantum dot imaging in the second near-infrared optical window: studies on reflectance fluorescence imaging depths by effective fluence rate and multiple image acquisition-
dc.typeArticle-
dc.contributor.college화학과-
dc.identifier.doi10.1117/1.JBO.20.4.046012-
dc.author.googleJung, Y-
dc.author.googleJeong, S-
dc.author.googleNayoun, W-
dc.author.googleAhn, B-
dc.author.googleKwag, J-
dc.author.googleKim, SG-
dc.author.googleKim, S-
dc.relation.volume20-
dc.relation.issue4-
dc.contributor.id10149571-
dc.relation.journalJOURNAL OF BIOMEDICAL OPTICS-
dc.relation.indexSCI급, SCOPUS 등재논문-
dc.relation.sciSCI-
dc.collections.nameJournal Papers-
dc.type.rimsART-
dc.identifier.bibliographicCitationJOURNAL OF BIOMEDICAL OPTICS, v.20, no.4-
dc.identifier.wosid000355282800021-
dc.date.tcdate2019-01-01-
dc.citation.number4-
dc.citation.titleJOURNAL OF BIOMEDICAL OPTICS-
dc.citation.volume20-
dc.contributor.affiliatedAuthorKim, S-
dc.identifier.scopusid2-s2.0-84929483942-
dc.description.journalClass1-
dc.description.journalClass1-
dc.description.wostc7-
dc.description.scptc7*
dc.date.scptcdate2018-10-274*
dc.type.docTypeArticle-
dc.subject.keywordPlusTO-NOISE RATIO-
dc.subject.keywordPlusNANOCRYSTALS-
dc.subject.keywordPlusPBS-
dc.subject.keywordAuthorquantum dots-
dc.subject.keywordAuthorinfrared imaging-
dc.subject.keywordAuthorcharge-coupled devices-
dc.subject.keywordAuthorfluorescence-
dc.subject.keywordAuthorimage enhancement-
dc.relation.journalWebOfScienceCategoryBiochemical Research Methods-
dc.relation.journalWebOfScienceCategoryOptics-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaBiochemistry & Molecular Biology-
dc.relation.journalResearchAreaOptics-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-

qr_code

  • mendeley

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher

김성지KIM, SUNG JEE
Dept of Chemistry
Read more

Views & Downloads

Browse