Open Access System for Information Sharing

Login Library

 

Article
Cited 35 time in webofscience Cited 37 time in scopus
Metadata Downloads

Improvement of ultrasound speckle image velocimetry using image enhancement techniques SCIE SCOPUS

Title
Improvement of ultrasound speckle image velocimetry using image enhancement techniques
Authors
Eun Seop YeomKwon Ho NamDong Kook PengLee, SJ
Date Issued
2014-01
Publisher
ELSEVIER SCIENCE BV
Abstract
Ultrasound-based techniques have been developed and widely used in noninvasive measurement of blood velocity. Speckle image velocimetry (SIV), which applies a cross-correlation algorithm to consecutive B-mode images of blood flow has often been employed owing to its better spatial resolution compared with conventional Doppler-based measurement techniques. The SIV technique utilizes speckles backscattered from red blood cell (RBC) aggregates as flow tracers. Hence, the intensity and size of such speckles are highly dependent on hemodynamic conditions. The grayscale intensity of speckle images varies along the radial direction of blood vessels because of the shear rate dependence of RBC aggregation. This inhomogeneous distribution of echo speckles decreases the signal-to-noise ratio (SNR) of a cross-correlation analysis and produces spurious results. In the present study, image-enhancement techniques such as contrast-limited adaptive histogram equalization (CLAHE), min/max technique, and subtraction of background image (SB) method were applied to speckle images to achieve a more accurate SIV measurement. A mechanical sector ultrasound scanner was used to obtain ultrasound speckle images from rat blood under steady and pulsatile flows. The effects of the image-enhancement techniques on SIV analysis were evaluated by comparing image intensities, velocities, and cross-correlation maps. The velocity profiles and wall shear rate (WSR) obtained from RBC suspension images were compared with the analytical solution for validation. In addition, the image-enhancement techniques were applied to in vivo measurement of blood flow in human vein. The experimental results of both in vitro and in vivo SIV measurements show that the intensity gradient in heterogeneous speckles has substantial influence on the cross-correlation analysis. The image-enhancement techniques used in this study can minimize errors encountered in ultrasound SIV measurement in which RBCs are used as flow tracers instead of exogenous contrast agents. (C) 2013 Elsevier B. V. All rights reserved.
Keywords
Ultrasound speckle images; Image-enhancement technique; Blood flow; RBC aggregation; PORCINE BLOOD; ERYTHROCYTE AGGREGATION; VELOCITY PROFILES; PULSATILE FLOW; ECHOGENICITY VARIATIONS; STENOSED TUBE; WHOLE-BLOOD; BRIGHT RING; ECHO PIV; IN-VITRO
URI
https://oasis.postech.ac.kr/handle/2014.oak/14585
DOI
10.1016/J.ULTRAS.2013.05.001
ISSN
0041-624X
Article Type
Article
Citation
Ultrasonics, vol. 54, no. 1, page. 205 - 216, 2014-01
Files in This Item:
There are no files associated with this item.

qr_code

  • mendeley

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher

이상준LEE, SANG JOON
Dept of Mechanical Enginrg
Read more

Views & Downloads

Browse