Open Access System for Information Sharing

Login Library

 

Article
Cited 7 time in webofscience Cited 7 time in scopus
Metadata Downloads
Full metadata record
Files in This Item:
There are no files associated with this item.
DC FieldValueLanguage
dc.contributor.authorShin, GW-
dc.contributor.authorKim, YT-
dc.contributor.authorHeo, HY-
dc.contributor.authorChung, B-
dc.contributor.authorSeo, TS-
dc.contributor.authorJung, GY-
dc.date.accessioned2016-03-31T08:56:34Z-
dc.date.available2016-03-31T08:56:34Z-
dc.date.created2012-09-28-
dc.date.issued2012-12-
dc.identifier.issn0173-0835-
dc.identifier.other2012-OAK-0000025873-
dc.identifier.urihttps://oasis.postech.ac.kr/handle/2014.oak/16346-
dc.description.abstractRecent improvements in the multiplex ligation-dependent probe amplification (MLPA) method promise successful multiplex analysis of various genetic markers. In particular, it has been demonstrated that elimination of the stuffer sequence included in MLPA probes for length-dependent analysis substantially simplifies the probe design process and improves the accuracy of the analysis. As is the case for other CE-based methods, MLPA could be further developed on a microchip platform. However, high-resolution analysis of short MLPA probes requires careful microchip operation. In this study, we developed a microchip device for the multiplex analysis of five food-borne pathogens using a stuffer-free probe set. Microchip channel design and electrophoresis operating conditions were first optimized for reproducible analysis, after which two sieving matrices were tested. Finally, the method was validated using DNA samples isolated from intentionally infected milk.-
dc.description.statementofresponsibilityX-
dc.languageEnglish-
dc.publisherWILEY-BLACKWELL-
dc.relation.isPartOfElectrophoresis-
dc.subjectCE-SSCP-
dc.subjectFood-borne pathogen-
dc.subjectMicrochip-
dc.subjectPEO-PPO-PEO triblock copolymer-
dc.subjectStuffer-free MLPA-
dc.subjectRESOLUTION CE-SSCP-
dc.subjectPATHOGEN DETECTION-
dc.subjectCAPILLARY-ELECTROPHORESIS-
dc.subjectSYSTEM-
dc.subjectMATRIX-
dc.titleTriblock copolymer-based microchip device for rapid analysis of stuffer-free multiplex ligation-dependent probe amplification products-
dc.typeArticle-
dc.contributor.college화학공학과-
dc.identifier.doi10.1002/ELPS.201200436-
dc.author.googleShin, GW-
dc.author.googleKim, YT-
dc.author.googleHeo, HY-
dc.author.googleChung, B-
dc.author.googleSeo, TS-
dc.author.googleJung, GY-
dc.relation.volume33-
dc.relation.issue23-
dc.relation.startpage3574-
dc.relation.lastpage3578-
dc.contributor.id10130678-
dc.relation.journalElectrophoresis-
dc.relation.indexSCI급, SCOPUS 등재논문-
dc.relation.sciSCI-
dc.collections.nameJournal Papers-
dc.type.rimsART-
dc.identifier.bibliographicCitationElectrophoresis, v.33, no.23, pp.3574 - 3578-
dc.identifier.wosid000312157200019-
dc.date.tcdate2019-01-01-
dc.citation.endPage3578-
dc.citation.number23-
dc.citation.startPage3574-
dc.citation.titleElectrophoresis-
dc.citation.volume33-
dc.contributor.affiliatedAuthorJung, GY-
dc.identifier.scopusid2-s2.0-84870537754-
dc.description.journalClass1-
dc.description.journalClass1-
dc.description.wostc7-
dc.description.scptc6*
dc.date.scptcdate2018-05-121*
dc.type.docTypeArticle-
dc.subject.keywordPlusRESOLUTION CE-SSCP-
dc.subject.keywordPlusPATHOGEN DETECTION-
dc.subject.keywordPlusCAPILLARY-ELECTROPHORESIS-
dc.subject.keywordPlusSYSTEM-
dc.subject.keywordPlusMATRIX-
dc.subject.keywordAuthorCE-SSCP-
dc.subject.keywordAuthorFood-borne pathogen-
dc.subject.keywordAuthorMicrochip-
dc.subject.keywordAuthorPEO-PPO-PEO triblock copolymer-
dc.subject.keywordAuthorStuffer-free MLPA-
dc.relation.journalWebOfScienceCategoryBiochemical Research Methods-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaBiochemistry & Molecular Biology-
dc.relation.journalResearchAreaChemistry-

qr_code

  • mendeley

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher

정규열JUNG, GYOO YEOL
Dept. of Chemical Enginrg
Read more

Views & Downloads

Browse