Open Access System for Information Sharing

Login Library

 

Article
Cited 56 time in webofscience Cited 58 time in scopus
Metadata Downloads

Retention mechanism of poly(ethylene oxide) in reversed-phase and normal-phase liquid chromatography SCIE SCOPUS

Title
Retention mechanism of poly(ethylene oxide) in reversed-phase and normal-phase liquid chromatography
Authors
Cho, DPark, SHong, JChang, T
Date Issued
2003-02-07
Publisher
ELSEVIER SCIENCE BV
Abstract
The retention behavior of low- and high-molecular-mass poly(ethylene oxide) (PEO) in reversed-phase (RP) and normal-phase (NP) liquid chromatography was investigated. In RPLC using a C-18 bonded silica stationary phase and an acetonitrile-water mixture mobile phase, the sorption process of PEO to the stationary phase showed DeltaHdegrees > 0 and DeltaSdegrees > 0. Therefore, PEO retention in RPLC separation is an energetically unfavorable, entropy-driven process, which results in an increase of PEO retention as the temperature increases. In addition, at the enthalpy-entropy compensation point the elution volume of PEO was very different from the column void volume. These observations are quite different from the RPLC retention behavior of many organic polymers. The peculiar retention behavior of PEO in RPLC separation can be understood in terms of the hydrophobic interaction of this class of typical amphiphilic compounds with the non-polar stationary phase, on the one hand, and with the aqueous mobile phase, on the other. The entropy gain due to the release of the solvated water molecules from the PEO chain and the stationary phase is believed to be responsible for the entropy-driven separation process. On the other hand, in NPLC using an amino-bonded silica stationary phase and an acetonitrile-water mixture mobile phase, PEO showed normal enthalpy-driven retention behavior: DeltaHdegrees < 0 and DeltaSdegrees < 0, with the retention decreasing with increasing temperature and PEO eluting near the column void volume at the enthalpy-entropy compensation point. Therefore, high-resolution temperature gradient NPLC separation of high-molecular-mass PEO samples can be achieved with relative ease. The molecular mass distribution of high-molecular-mass PEO was found to be much narrower than that measured by size-exclusion chromatography. (C) 2002 Elsevier Science B.V. All rights reserved.
Keywords
retention mechanism; temperature effects; poly(ethylene oxide); HIGH-PERFORMANCE LIQUID; GRADIENT INTERACTION CHROMATOGRAPHY; HYDROPHOBIC INTERACTION CHROMATOGRAPHY; POLYETHYLENE-GLYCOL OLIGOMERS; EVAPORATIVE LIGHT-SCATTERING; ADSORPTION CHROMATOGRAPHY; PROTEIN-STRUCTURE; MOLECULAR-MASS; SEPARATION; POLYETHERS
URI
https://oasis.postech.ac.kr/handle/2014.oak/18710
DOI
10.1016/S0021-9673(02)01953-2
ISSN
0021-9673
Article Type
Article
Citation
JOURNAL OF CHROMATOGRAPHY A, vol. 986, no. 2, page. 191 - 198, 2003-02-07
Files in This Item:
There are no files associated with this item.

qr_code

  • mendeley

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher

장태현CHANG, TAIHYUN
Div of Advanced Materials Science
Read more

Views & Downloads

Browse