The effective coefficient of secondary electron emission in plasma display panel
SCIE
SCOPUS
- Title
- The effective coefficient of secondary electron emission in plasma display panel
- Authors
- Hur, MS; Lee, JK; Kim, HC; Kang, BK
- Date Issued
- 2001-10
- Publisher
- IEEE-INST ELECTRICAL ELECTRONICS ENGI
- Abstract
- The effective secondary electron emission coefficient (SEEC) in a plasma display panel (PDP) is estimated by comparing the Paschen breakdown curves from simulations with the experiment. It is found that the effective SEEC in PDP is dependent on the ratio of electric field to pressure. The estimated values are 0.59 similar to0.79 for the pure Ne and 0.1 similar to0.13 for the Ne-Xe (96/4) mixture, respectively.
- Keywords
- back-scattering; discharge; Paschen breakdown curve; plasma display; secondary electron; simulation; CELL
- URI
- https://oasis.postech.ac.kr/handle/2014.oak/19309
- DOI
- 10.1109/27.964487
- ISSN
- 0093-3813
- Article Type
- Article
- Citation
- IEEE TRANSACTIONS ON PLASMA SCIENCE, vol. 29, no. 5, page. 861 - 863, 2001-10