Impedance measurement for various vacuum components in Pohang Light Source Storage ring SCIE SCOPUS

Title
Impedance measurement for various vacuum components in Pohang Light Source Storage ring
Authors
Han, DHKwon, MKim, YS
Date Issued
1996-04
Publisher
JAPAN J APPLIED PHYSICS
Abstract
The Pohang Light Source (PLS) is a 2 GeV, third-generation synchrotron light source which was recently commissioned. Loss factor measurements were carried out for various storage ring vacuum components using the synthetic pulse technique. The measurement was done for bunch lengths (sigma(l)) ranging from 7.1 to 30 mm. The measured devices were elliptical and circular photon masks, bellows with elliptical and circular cross sections, ellipse-to-diamond transition, ellipse-to-ellipse transition, beam position monitor chamber, and circular T-piece. Broad-band impedances were obtained by fitting the measured loss factors to broad-band resonator model. The total broad-band impedance of 250 devices was 0.17 Omega, which is a small fraction of the total machine impedance budget as expected in the calculation.
Keywords
light source; storage ring; wake-field; loss factor; broad-band impedance; vacuum components
URI
https://oasis.postech.ac.kr/handle/2014.oak/21569
DOI
10.1143/JJAP.35.2290
ISSN
0021-4922
Article Type
Article
Citation
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, vol. 35, no. 4A, page. 2290 - 2295, 1996-04
Files in This Item:
There are no files associated with this item.

qr_code

  • mendeley

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher

김영수KIM, YOUNG SOO
Dept of Electrical Enginrg
Read more

Views & Downloads

Browse