Open Access System for Information Sharing

Login Library

 

Article
Cited 2 time in webofscience Cited 5 time in scopus
Metadata Downloads

CALCULATION OF CAPTURE COEFFICIENTS FOR A CYLINDRICAL CRYOPUMP SCIE SCOPUS

Title
CALCULATION OF CAPTURE COEFFICIENTS FOR A CYLINDRICAL CRYOPUMP
Authors
LEE, JWLEE, YK
Date Issued
1991-01
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Abstract
A new efficient method has been developed for calculating the pumping efficiency of a cryopump for different types of gases, which uses the geometric view factors between the surface elements of a cryopump. This method is as accurate as the Monte Carlo method, but much faster and more efficient when a systematic change in the system parameters is investigated. The method is applied for investigating the effect of cryopanel geometry on the pumping characteristics of cryopump arrays for different types of gases. One major result from such calculation is that the diameter of the cryopanel should be about 0.6 times that of the pumpbody diameter in order to give maximum pumping of He and H2 by the cryosorption element attached on the reverse side of the panel.
URI
https://oasis.postech.ac.kr/handle/2014.oak/22275
DOI
10.1016/0042-207X(91)90936-D
ISSN
0042-207X
Article Type
Article
Citation
VACUUM, vol. 42, no. 8-9, page. 555 - 560, 1991-01