Open Access System for Information Sharing

Login Library

 

Article
Cited 11 time in webofscience Cited 16 time in scopus
Metadata Downloads
Full metadata record
Files in This Item:
There are no files associated with this item.
DC FieldValueLanguage
dc.contributor.authorJe, Y-
dc.contributor.authorLee, H-
dc.contributor.authorPark, J-
dc.contributor.authorMoon, W-
dc.date.accessioned2016-04-01T02:45:23Z-
dc.date.available2016-04-01T02:45:23Z-
dc.date.created2010-11-19-
dc.date.issued2010-06-
dc.identifier.issn0001-4966-
dc.identifier.other2010-OAK-0000021784-
dc.identifier.urihttps://oasis.postech.ac.kr/handle/2014.oak/25709-
dc.description.abstractAn ultrasonic radiator is developed to generate a difference frequency sound from two frequencies of ultrasound in air with a parametric array. A design method is proposed for an ultrasonic radiator capable of generating highly directive, high-amplitude ultrasonic sound beams at two different frequencies in air based on a modification of the stepped-plate ultrasonic radiator. The stepped-plate ultrasonic radiator was introduced by Gallego-Juarez [Ultrasonics 16, 267-271 (1978)] in their previous study and can effectively generate highly directive, large-amplitude ultrasonic sounds in air, but only at a single frequency. Because parametric array sources must be able to generate sounds at more than one frequency, a design modification is crucial to the application of a stepped-plate ultrasonic radiator as a parametric array source in air. The aforementioned method was employed to design a parametric radiator for use in air. A prototype of this design was constructed and tested to determine whether it could successfully generate a difference frequency sound with a parametric array. The results confirmed that the proposed single small-area transducer was suitable as a parametric radiator in air. (c) 2010 Acoustical Society of America. [DOI: 10.1121/1.3397445]-
dc.description.statementofresponsibilityX-
dc.languageEnglish-
dc.publisherACOUSTICAL SOC AMER AMER INST PHYSICS-
dc.relation.isPartOfJOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA-
dc.subjectacoustic parametric devices-
dc.subjectacoustic radiators-
dc.subjectultrasonic transducer arrays-
dc.subjectultrasonic waves-
dc.subjectMICROMACHINED ULTRASONIC TRANSDUCERS-
dc.subjectAIR-
dc.titleA stepped-plate bi-frequency source for generating a difference frequency sound with a parametric array-
dc.typeArticle-
dc.contributor.college기계공학과-
dc.identifier.doi10.1121/1.3397445-
dc.author.googleJe, Y-
dc.author.googleLee, H-
dc.author.googlePark, J-
dc.author.googleMoon, W-
dc.relation.volume127-
dc.relation.issue6-
dc.relation.startpage3494-
dc.relation.lastpage3502-
dc.contributor.id10106244-
dc.relation.journalJOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA-
dc.relation.indexSCI급, SCOPUS 등재논문-
dc.relation.sciSCI-
dc.collections.nameJournal Papers-
dc.type.rimsART-
dc.identifier.bibliographicCitationJOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, v.127, no.6, pp.3494 - 3502-
dc.identifier.wosid000278626500025-
dc.date.tcdate2019-02-01-
dc.citation.endPage3502-
dc.citation.number6-
dc.citation.startPage3494-
dc.citation.titleJOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA-
dc.citation.volume127-
dc.contributor.affiliatedAuthorMoon, W-
dc.identifier.scopusid2-s2.0-77953591223-
dc.description.journalClass1-
dc.description.journalClass1-
dc.description.wostc7-
dc.description.scptc10*
dc.date.scptcdate2018-05-121*
dc.type.docTypeArticle-
dc.subject.keywordAuthoracoustic parametric devices-
dc.subject.keywordAuthoracoustic radiators-
dc.subject.keywordAuthorultrasonic transducer arrays-
dc.subject.keywordAuthorultrasonic waves-
dc.relation.journalWebOfScienceCategoryAcoustics-
dc.relation.journalWebOfScienceCategoryAudiology & Speech-Language Pathology-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaAcoustics-
dc.relation.journalResearchAreaAudiology & Speech-Language Pathology-

qr_code

  • mendeley

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Views & Downloads

Browse