DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ji-Yong Um | - |
dc.contributor.author | Kim, YJ | - |
dc.contributor.author | Seong-Eun Cho | - |
dc.contributor.author | Min-Kyun Chae | - |
dc.contributor.author | Song, J | - |
dc.contributor.author | Kim, B | - |
dc.contributor.author | Seunghun Lee | - |
dc.contributor.author | Jihoon Bang | - |
dc.contributor.author | Youngil Kim | - |
dc.contributor.author | Kyungil Cho | - |
dc.contributor.author | Kim, B | - |
dc.contributor.author | SIM, JAE YOON | - |
dc.contributor.author | Park, HJ | - |
dc.date.accessioned | 2016-04-01T07:47:59Z | - |
dc.date.available | 2016-04-01T07:47:59Z | - |
dc.date.created | 2015-02-20 | - |
dc.date.issued | 2014-12 | - |
dc.identifier.issn | 1932-4545 | - |
dc.identifier.other | 2015-OAK-0000033081 | - |
dc.identifier.uri | https://oasis.postech.ac.kr/handle/2014.oak/26885 | - |
dc.description.abstract | To reduce the memory area, a two-stage RX beamformer (BF) chip with 64 channels is proposed for the ultrasound medical imaging with a 2D CMUT array. The chip retrieved successfully two B-mode phantom images with a steering angle from -45 degrees to +45 degrees, the maximum delay range of 8 mu s, and the delay resolution of 6.25 ns. An analog-digital hybrid BF (HBF) is chosen for the proposed chip to utilize the easy beamforming operation in the digital domain and also to reduce chip area by minimizing the number of ADCs. The chip consists of eight analog beamformers (ABF) for the 1st-stage and a digital beamformer (DBF) for the 2nd-stage. The two-stage architecture reduces the memory area of both ABF and DBF by around four times. The DBF circuit is divided into three steps to further reduce the digital FIFO memory area by around twice. Coupled with the non-uniform sampling scheme, the proposed two-stage HBF chip reduces the total memory area by around 40 times compared to the uniform-sampling single-stage BF chip. The chip fabricated in a 0.13-mu m CMOS process occupies the area of 19.4 mm(2), and dissipates 1.14 W with the analog supply of 3.3 V and the digital supply of 1.2 V. | - |
dc.description.statementofresponsibility | X | - |
dc.language | English | - |
dc.publisher | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC | - |
dc.relation.isPartOf | IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS | - |
dc.title | An Analog-Digital Hybrid RX Beamformer Chip With Non-Uniform Sampling for Ultrasound Medical Imaging With 2D CMUT Array | - |
dc.type | Article | - |
dc.contributor.college | 전자전기공학과 | - |
dc.identifier.doi | 10.1109/TBCAS.2014.2375958 | - |
dc.author.google | Um, JY | - |
dc.author.google | Kim, YJ | - |
dc.author.google | Cho, SE | - |
dc.author.google | Chae, MK | - |
dc.author.google | Song, J | - |
dc.author.google | Kim, B | - |
dc.author.google | Lee, S | - |
dc.author.google | Bang, J | - |
dc.author.google | Kim, Y | - |
dc.author.google | Cho, K | - |
dc.author.google | Sim, JY | - |
dc.author.google | Park, HJ | - |
dc.relation.volume | 8 | - |
dc.relation.issue | 6 | - |
dc.relation.startpage | 799 | - |
dc.relation.lastpage | 809 | - |
dc.contributor.id | 10100874 | - |
dc.relation.journal | IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS | - |
dc.relation.sci | SCIE | - |
dc.collections.name | Journal Papers | - |
dc.type.rims | ART | - |
dc.identifier.bibliographicCitation | IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, v.8, no.6, pp.799 - 809 | - |
dc.identifier.wosid | 000348221700006 | - |
dc.date.tcdate | 2019-02-01 | - |
dc.citation.endPage | 809 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 799 | - |
dc.citation.title | IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS | - |
dc.citation.volume | 8 | - |
dc.contributor.affiliatedAuthor | Seong-Eun Cho | - |
dc.contributor.affiliatedAuthor | Min-Kyun Chae | - |
dc.contributor.affiliatedAuthor | Kim, B | - |
dc.contributor.affiliatedAuthor | Youngil Kim | - |
dc.contributor.affiliatedAuthor | SIM, JAE YOON | - |
dc.contributor.affiliatedAuthor | Park, HJ | - |
dc.identifier.scopusid | 2-s2.0-84921492180 | - |
dc.description.journalClass | 1 | - |
dc.description.journalClass | 1 | - |
dc.description.wostc | 10 | - |
dc.description.scptc | 11 | * |
dc.date.scptcdate | 2018-05-121 | * |
dc.type.docType | Article; Proceedings Paper | - |
dc.subject.keywordPlus | REAL-TIME | - |
dc.subject.keywordPlus | MATRIX TRANSDUCER | - |
dc.subject.keywordPlus | CIRCUIT | - |
dc.subject.keywordPlus | DESIGN | - |
dc.subject.keywordAuthor | Analog-digital hybrid | - |
dc.subject.keywordAuthor | non-uniform sampling | - |
dc.subject.keywordAuthor | RX beamformer | - |
dc.subject.keywordAuthor | two-stage architecture | - |
dc.subject.keywordAuthor | ultrasound | - |
dc.relation.journalWebOfScienceCategory | Engineering, Biomedical | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
library@postech.ac.kr Tel: 054-279-2548
Copyrights © by 2017 Pohang University of Science ad Technology All right reserved.