Open Access System for Information Sharing

Login Library

 

Article
Cited 20 time in webofscience Cited 19 time in scopus
Metadata Downloads
Full metadata record
Files in This Item:
There are no files associated with this item.
DC FieldValueLanguage
dc.contributor.authorLee, JH-
dc.contributor.authorLee, S-
dc.contributor.authorGHO, YONG SONG-
dc.contributor.authorSong, IS-
dc.contributor.authorTchah, H-
dc.contributor.authorKim, MJ-
dc.contributor.authorKim, KH-
dc.date.accessioned2016-04-01T07:48:41Z-
dc.date.available2016-04-01T07:48:41Z-
dc.date.created2015-06-25-
dc.date.issued2015-03-
dc.identifier.issn0014-4835-
dc.identifier.other2015-OAK-0000033040-
dc.identifier.urihttps://oasis.postech.ac.kr/handle/2014.oak/26898-
dc.description.abstractHigh-resolution imaging of the cornea is important for studying corneal diseases at cellular levels. Confocal microscopy (CM) has been widely used in the clinic, and two-photon microscopy (TPM) has recently been introduced in various pre-clinical studies. We compared the performance of CM and TPM in normal mouse corneas and neovascularized mouse corneas induced by suturing. Balb/C mice and C57BL/6 mice expressing green fluorescent protein (GFP) were used to compare modalities based on intrinsic contrast and extrinsic fluorescence contrast. CM based on reflection (CMR), CM based on fluorescence (CMF), and TPM based on intrinsic/extrinsic fluorescence and second harmonic generation (SHG) were compared by imaging the same sections of mouse corneas sequentially in vivo. In normal mouse corneas, CMR visualized corneal cell morphologies with some background noise, and CMF visualized GFP expressing corneal cells clearly. TPM visualized corneal cells and collagen in the stroma based on fluorescence and SHG, respectively. However, in neovascularized mouse corneas, CMR could not resolve cells deep inside the cornea due to high background noise from the effects of increased structural irregularity induced by suturing. CMF and TPM visualized cells and induced vasculature better than CMR because both collect signals from fluorescent cells only. Both CMF and TPM had signal decays with depth due to the structural irregularity, with CMF having faster signal decay than TPM. CMR, CMF, and TPM showed different degrees of image degradation in neovascularized mouse corneas. (C) 2015 Elsevier Ltd. All rights reserved.-
dc.description.statementofresponsibilityX-
dc.languageEnglish-
dc.publisherACADEMIC PRESS LTD- ELSEVIER SCIENCE LTD-
dc.relation.isPartOfEXPERIMENTAL EYE RESEARCH-
dc.titleComparison of confocal microscopy and two-photon microscopy in mouse cornea in vivo-
dc.typeArticle-
dc.contributor.college생명과학과-
dc.identifier.doi10.1016/J.EXER.2015.01.013-
dc.author.googleLee, JH-
dc.author.googleLee, S-
dc.author.googleGho, YS-
dc.author.googleSong, IS-
dc.author.googleTchah, H-
dc.author.googleKim, MJ-
dc.author.googleKim, KH-
dc.relation.volume132-
dc.relation.startpage101-
dc.relation.lastpage108-
dc.contributor.id10138843-
dc.relation.journalEXPERIMENTAL EYE RESEARCH-
dc.relation.sciSCI-
dc.collections.nameJournal Papers-
dc.type.rimsART-
dc.identifier.bibliographicCitationEXPERIMENTAL EYE RESEARCH, v.132, pp.101 - 108-
dc.identifier.wosid000351189900012-
dc.date.tcdate2019-02-01-
dc.citation.endPage108-
dc.citation.startPage101-
dc.citation.titleEXPERIMENTAL EYE RESEARCH-
dc.citation.volume132-
dc.contributor.affiliatedAuthorGHO, YONG SONG-
dc.contributor.affiliatedAuthorKim, KH-
dc.identifier.scopusid2-s2.0-84922683308-
dc.description.journalClass1-
dc.description.journalClass1-
dc.description.wostc8-
dc.description.scptc7*
dc.date.scptcdate2018-05-121*
dc.type.docTypeArticle-
dc.subject.keywordPlusMULTIPHOTON MICROSCOPY-
dc.subject.keywordPlusFLUORESCENCE-
dc.subject.keywordPlusLIVE-
dc.subject.keywordAuthorConfocal microscopy-
dc.subject.keywordAuthorTwo-photon microscopy-
dc.subject.keywordAuthorHigh-resolution 3D imaging-
dc.subject.keywordAuthorIn vivo imaging-
dc.subject.keywordAuthorAnimal model-
dc.subject.keywordAuthorCorneal suture model-
dc.relation.journalWebOfScienceCategoryOphthalmology-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOphthalmology-

qr_code

  • mendeley

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher

김기현KIM, KI HEAN
Dept of Mechanical Enginrg
Read more

Views & Downloads

Browse