Open Access System for Information Sharing

Login Library

 

Article
Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads
Full metadata record
Files in This Item:
There are no files associated with this item.
DC FieldValueLanguage
dc.contributor.authorKIM, KR-
dc.contributor.authorPARK, J-
dc.contributor.authorKIM, HG-
dc.contributor.authorKIM, HS-
dc.contributor.authorHWANG, WH-
dc.contributor.authorYOON, CC-
dc.contributor.authorCHO, EB-
dc.contributor.authorKWON, HJ-
dc.contributor.authorCHO, YS-
dc.contributor.authornull-
dc.date.accessioned2016-04-01T08:35:39Z-
dc.date.available2016-04-01T08:35:39Z-
dc.date.issued2009-05-
dc.identifier.citationJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.identifier.citationv.54-
dc.identifier.citationno.5-
dc.identifier.citationpp.1952-1960-
dc.identifier.issn0374-4884-
dc.identifier.other2009-OAK-0000018338-
dc.identifier.urihttps://oasis.postech.ac.kr/handle/2014.oak/28324-
dc.description.abstractThe Proton Engineering Frontier Project (PEFP) has been tinder development to establish a 100 MeV proton accelerator complex in Korea. As a front part of the 100-MeV machine, 20-MeV proton accelerator systems were installed and tested at the site of the Korea Atomic Energy Research Institute (KEARI). The PEFP accelerator structures, such as the drift tube linac (QTL), require a water-cooling-system-based thermal tuning system to regulate the resonant frequency (rf) of the drift tube (DT) cavity to 350 MHz. We have designed and fabricated a prototype water pumping skid that has two water cooling channels of a by-passing cooling water (primary loop) and a plate heat exchanger (secondary loop). The required operating temperature can be achieved by mixing the coolants of each channel. The temperature control around the operating point could be achieved using two independent PI controllers installed in the two loops. The system set-up and test were conducted for the 20 MeV DTL systems. The results indicate that the temperature control of the drift tube cavities is available within design range of 27 6 degrees C with a precision of less than +/- 0.1 degrees C to regulate the resonant frequency of the drift tube cavities.-
dc.description.statementofresponsibilityX-
dc.publisherKOREAN PHYSICAL SOC-
dc.subjectDrift tube linac-
dc.subjectRF resonant frequency-
dc.subjectWater pumping skid-
dc.subjectMid-ranging PI Control-
dc.subjectLINAC-
dc.titleThermal Tuning System for PEFP DTL Resonant Frequency Control-
dc.typeArticle-
dc.author.googleKIM, KR-
dc.author.googlePARK, J-
dc.author.googleKIM, HG-
dc.author.googleKIM, HS-
dc.author.googleHWANG, WH-
dc.author.googleYOON, CC-
dc.author.googleCHO, EB-
dc.author.googleKWON, HJ-
dc.author.googleCHO, YS-
dc.relation.volume54-
dc.relation.issue5-
dc.relation.startpage1952-
dc.relation.lastpage1960-
dc.publisher.locationKO-
dc.relation.journalJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.relation.indexSCI급, SCOPUS 등재논문-
dc.relation.sciSCI-
dc.collections.nameJournal Papers-
dc.type.docTypeArticle-

qr_code

  • mendeley

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Views & Downloads

Browse