Open Access System for Information Sharing

Login Library

 

Article
Cited 6 time in webofscience Cited 7 time in scopus
Metadata Downloads
Full metadata record
Files in This Item:
There are no files associated with this item.
DC FieldValueLanguage
dc.contributor.authorYong, HS-
dc.contributor.authorKang, EY-
dc.contributor.authorKim, YK-
dc.contributor.authorWoo, OH-
dc.contributor.authorShin, BK-
dc.contributor.authorOh, CH-
dc.contributor.authorJe, JH-
dc.contributor.authorHan, H-
dc.contributor.authorSeo, JS-
dc.date.accessioned2016-04-01T08:42:53Z-
dc.date.available2016-04-01T08:42:53Z-
dc.date.created2009-08-17-
dc.date.issued2009-06-30-
dc.identifier.issn0513-5796-
dc.identifier.other2009-OAK-0000017654-
dc.identifier.urihttps://oasis.postech.ac.kr/handle/2014.oak/28602-
dc.description.abstractPurpose: The purpose of this study is to evaluate the feasibility of phase contrast X-ray microtomography and microradiography, using a polychromatic synchrotron X-ray, for analysis of the mouse lung microstructure. Materials and Methods: Normal mice were used for experiments. Some of the mouse lungs were prepared by the lung fixation-inflation method. The resulting sponge-like inflated lung samples were used for microtomography. The remaining mouse lungs were cut into 10 um sections and were used for microradiography and optical microscopic correlation. The experiments on mouse lung samples were per-formed at the 7B2 beamline of the Pohang Light Source in Korea. Results: Phase contrast X-ray microtomography of inflated lung samples showed individual alveolar structure on 3-D reconstruction. Phase contrast microradiographs of thin lung samples showed microstructure of lung, such as alveoli and bronchioles, and were well correlated with optical microscopic images. Conclusions: The results indicate that the phase contrast X-ray microtomography and microradiography using polychromatic synchrotron X-ray is feasible for evaluation of microstructure of the lung.-
dc.description.statementofresponsibilityX-
dc.languageEnglish-
dc.publisherYONSEI UNIV COLLEGE MEDICINE-
dc.relation.isPartOfYONSEI MEDICAL JOURNAL-
dc.subjectPhase contrast microradiography-
dc.subjectpolychromatic synchrotron X-ray-
dc.subjectrefraction enhanced imaging-
dc.subjectlung-
dc.subjectRABBIT LUNGS-
dc.subjectINJURY-
dc.subjectCT-
dc.titlePhase Contrast Microradiography of Mouse Lung Using Synchrotron X-ray: Correlation with Optical Microscopy-
dc.typeArticle-
dc.contributor.college신소재공학과-
dc.identifier.doi10.3349/ymj.2009.50.3.422-
dc.author.googleYong, HS-
dc.author.googleKang, EY-
dc.author.googleKim, YK-
dc.author.googleWoo, OH-
dc.author.googleShin, BK-
dc.author.googleOh, CH-
dc.author.googleJe, JH-
dc.author.googleHan, H-
dc.author.googleSeo, JS-
dc.relation.volume50-
dc.relation.issue3-
dc.relation.startpage422-
dc.relation.lastpage426-
dc.contributor.id10123980-
dc.relation.journalYONSEI MEDICAL JOURNAL-
dc.relation.indexSCI급, SCOPUS 등재논문-
dc.relation.sciSCIE-
dc.collections.nameJournal Papers-
dc.type.rimsART-
dc.identifier.bibliographicCitationYONSEI MEDICAL JOURNAL, v.50, no.3, pp.422 - 426-
dc.identifier.wosid000267325500017-
dc.date.tcdate2019-02-01-
dc.citation.endPage426-
dc.citation.number3-
dc.citation.startPage422-
dc.citation.titleYONSEI MEDICAL JOURNAL-
dc.citation.volume50-
dc.contributor.affiliatedAuthorJe, JH-
dc.identifier.scopusid2-s2.0-67651171458-
dc.description.journalClass1-
dc.description.journalClass1-
dc.description.wostc5-
dc.type.docTypeArticle-
dc.subject.keywordPlusRABBIT LUNGS-
dc.subject.keywordPlusINJURY-
dc.subject.keywordPlusCT-
dc.subject.keywordAuthorPhase contrast microradiography-
dc.subject.keywordAuthorpolychromatic synchrotron X-ray-
dc.subject.keywordAuthorrefraction enhanced imaging-
dc.subject.keywordAuthorlung-
dc.relation.journalWebOfScienceCategoryMedicine, General & Internal-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaGeneral & Internal Medicine-

qr_code

  • mendeley

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher

제정호JE, JUNG HO
Dept of Materials Science & Enginrg
Read more

Views & Downloads

Browse