An Early Stage Interturn Fault Diagnosis of PMSMs by Using Negative-Sequence Components SCIE SCOPUS

Title
An Early Stage Interturn Fault Diagnosis of PMSMs by Using Negative-Sequence Components
Authors
Jeong, H.Moon, S.Kim, S.W.
Date Issued
2017-07
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Abstract
This paper proposes an early stage interturn short-circuit fault (ISCF) diagnosis method for permanent magnet synchronous machines. A fault indicator is suggested based on a new theoretical analysis of the relationship between the fault current and the rotor speed. The fault indicator is shown to be robust to the rotor speed changes in slight ISCFs. It is calculated by introducing negative-sequence components (NSCs). It is shown that the fault indicator using NSCs can diagnose slighter ISCFs than that using zero-sequence components. Experimental results demonstrate the effectiveness of the proposed method for diagnosing early stage ISCFs with a small number of short-circuited turns and low fault current. ? 1982-2012 IEEE.
URI
https://oasis.postech.ac.kr/handle/2014.oak/50975
DOI
10.1109/TIE.2017.2677355
ISSN
0278-0046
Article Type
Article
Citation
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, vol. 64, no. 7, page. 5701 - 5708, 2017-07