Open Access System for Information Sharing

Login Library

 

Article
Cited 3 time in webofscience Cited 8 time in scopus
Metadata Downloads

Compressed Sensing With a Gaussian Scale Mixture Model for Limited View Photoacoustic Computed Tomography In Vivo SCIE SCOPUS

Title
Compressed Sensing With a Gaussian Scale Mixture Model for Limited View Photoacoustic Computed Tomography In Vivo
Authors
Meng, JingLiu, ChengboKim, JeesuKim, ChulhongSong, Liang
Date Issued
2018-10
Publisher
SAGE PUBLICATIONS INC
Abstract
Photoacoustic computed tomography using an ultrasonic array is an attractive noninvasive imaging modality for many biomedical applications. However, the potentially long data acquisition time of array-based photoacoustic computed tomography-usually due to the required time-multiplexing for multiple laser pulses-decreases its applicability for rapid disease diagnoses and the successive monitoring of physiological functions. Compressed sensing is used to improve the imaging speed of photoacoustic computed tomography by decreasing the amount of acquired data; however, the imaging quality can be limited when fewer measurements are used, as traditional compressed sensing considers only the sparsity of the signals in the imaging process. In this work, an advanced compressed sensing reconstruction framework with a Wiener linear estimation-based Gaussian scale mixture model was developed for limited view photoacoustic computed tomography. In this method, the structure dependencies of signals in the wavelet domain were incorporated into the imaging framework through the Gaussian scale mixture model, and an operator based on the Wiener linear estimation was designed to filter the reconstruction artifacts. Phantom and human forearm imaging were performed to verify the developed method. The results demonstrated that compressed sensing with a Wiener linear estimation-based Gaussian scale mixture model more effectively suppressed the reconstruction artifacts of sparse-sampling photoacoustic computed tomography and recovered photoacoustic images with a higher contrast-to-noise ratio and edge resolution than the traditional compressed sensing method. This work may promote the development of low-cost photoacoustic computed tomography techniques with rapid data acquisition and enhance the performance of photoacoustic computed tomography in various biomedical studies.
URI
https://oasis.postech.ac.kr/handle/2014.oak/94944
DOI
10.1177/1533033818808222
ISSN
1533-0346
Article Type
Article
Citation
TECHNOLOGY IN CANCER RESEARCH & TREATMENT, vol. 17, 2018-10
Files in This Item:
There are no files associated with this item.

qr_code

  • mendeley

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher

김철홍KIM, CHULHONG
Dept of Electrical Enginrg
Read more

Views & Downloads

Browse