DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ha, Hojin | - |
dc.contributor.author | Koo, Hyun Jung | - |
dc.contributor.author | Huh, Hyung Kyu | - |
dc.contributor.author | Kim, Guk Bae | - |
dc.contributor.author | Kweon, Jihoon | - |
dc.contributor.author | Kim, Namkug | - |
dc.contributor.author | Kim, Young-Hak | - |
dc.contributor.author | Kang, Joon-Won | - |
dc.contributor.author | Lim, Tae-Hwan | - |
dc.contributor.author | Song, Jae-Kwan | - |
dc.contributor.author | Lee, Sang Joon | - |
dc.contributor.author | Yang, Dong Hyun | - |
dc.date.accessioned | 2019-04-07T17:52:07Z | - |
dc.date.available | 2019-04-07T17:52:07Z | - |
dc.date.created | 2018-09-03 | - |
dc.date.issued | 2018-06 | - |
dc.identifier.issn | 1932-6203 | - |
dc.identifier.uri | https://oasis.postech.ac.kr/handle/2014.oak/95864 | - |
dc.description.abstract | Although hemodynamic influence of the subprosthetic tissue, termed as pannus, may contribute to prosthetic aortic valve dysfunction, the relationship between pannus extent and hemodynamics in the prosthetic valve has rarely been reported. We investigated the fluid dynamics of pannus formation using in vitro experiments with particle image velocimetry. Subvalvular pannus formation caused substantial changes in prosthetic valve transvalvular peak velocity, transvalvular pressure gradient (TPG) and opening angle. Maximum flow velocity and corresponding TPG were mostly affected by pannus width. When the pannus width was 25% of the valve diameter, pannus formation elevated TPG to >2.5 times higher than that without pannus formation. Opening dysfunction was observed only for a pannus involvement angle of 360 degrees. Although circumferential pannus with an involvement angle of 360 degrees decreased the opening angle of the valve from approximately 82 degrees to 58 degrees, eccentric pannus with an involvement angle of 180 degrees did not induce valve opening dysfunction. The pannus involvement angle largely influenced the velocity flow field at the aortic sinus and corresponding hemodynamic indices, including wall shear stress, principal shear stress and viscous energy loss distributions. Substantial discrepancy between the velocity-based TPG estimation and direct pressure measurements was observed for prosthetic valve flow with pannus formation. | - |
dc.language | English | - |
dc.publisher | Public Library of Science | - |
dc.relation.isPartOf | PLoS ONE | - |
dc.title | Effect of pannus formation on the prosthetic heart valve: In vitro demonstration using particle image velocimetry | - |
dc.type | Article | - |
dc.identifier.doi | 10.1371/journal.pone.0199792 | - |
dc.type.rims | ART | - |
dc.identifier.bibliographicCitation | PLoS ONE, v.13, no.6 | - |
dc.identifier.wosid | 000436645400071 | - |
dc.citation.number | 6 | - |
dc.citation.title | PLoS ONE | - |
dc.citation.volume | 13 | - |
dc.contributor.affiliatedAuthor | Lee, Sang Joon | - |
dc.identifier.scopusid | 2-s2.0-85049206363 | - |
dc.description.journalClass | 1 | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | Y | - |
dc.type.docType | Article | - |
dc.subject.keywordPlus | RECOMMENDATIONS | - |
dc.subject.keywordPlus | GUIDELINES | - |
dc.subject.keywordPlus | WALL SHEAR-STRESS | - |
dc.subject.keywordPlus | PULSATILE SWIRLING FLOW | - |
dc.subject.keywordPlus | AORTIC-VALVE | - |
dc.subject.keywordPlus | EUROPEAN ASSOCIATION | - |
dc.subject.keywordPlus | AMERICAN SOCIETY | - |
dc.subject.keywordPlus | ASCENDING AORTA | - |
dc.subject.keywordPlus | CARDIAC CT | - |
dc.subject.keywordPlus | ECHOCARDIOGRAPHY | - |
dc.relation.journalWebOfScienceCategory | Multidisciplinary Sciences | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Science & Technology - Other Topics | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.
library@postech.ac.kr Tel: 054-279-2548
Copyrights © by 2017 Pohang University of Science ad Technology All right reserved.